  august 2013 docid024389 rev 1 1/11 AN4275 application note iec 61000-4-5 standard overview introduction the objective of this document is to briefly explain the iec 61000-4-5 standards and to show the benefits of having a range of protection devices specified according to this standard. for further details on iec 61000-4-5 refer to the international electrotechnical commission web site. industrial and consumer equipment are subjected to various surges. here are the main ones: ? iec 61000-4-2: esd surges affect most of consumer equipment. the more stressful esd standard is iec 61000-4-2 (few tens of ns duration) but other standards such as human body model (hbm), machine model (mm) exist. ? iec 61000-4-4: this st andard is made to check the capability of the equipment to survive repetitive electrical fast transients and bursts. ? iec 61000-4-5: lightning and industrial surg es modeled by iec 61000-4-5. this is the one we will describe in this document. ? telecommunication lines are exposed to lightning either directly on the equipment or due to induced effect because of ground potential change. in addition to these surges, a telecommunication line may also be disturbed by either power induction or power contact with main ac lines . depending on the country, these surges have been mainly modeled in: ? telcordia gr-1089 core for america with 2/10 s and 10/1000 s surges ? itu-t k series for the rest of the world with 10/700 s surges www.st.com
iec 61000-4-5 AN4275 2/11 docid024389 rev 1 1 iec 61000-4-5 power lines are subjected to switching and lightning transients. 1.1 power system switching transients power system switching transients can be separated into transients associated with: ? major power system switching disturbances , such as capacitor bank switching ? minor local switching activity or load changes in the power distribution system ? resonating circuits associated with s witching devices, su ch as thyristors ? various system faults, such as short circuits and arcing faults to the grounding system of the installation 1.2 lightning transients the major mechanisms by which lightning pr oduces surge voltages are the following: ? direct lightning strokes to outdoor circuits injecting high currents and producing over voltages. ? indirect lightning strikes (i .e. strikes between or within clouds or to nearby objects which produce electromagnetic fields) that induce voltages/currents on the conductors outside and/or inside a building. ? lightning ground current flows resulting fr om nearby direct-to-earth discharges coupling into the common ground paths of the grounding system of the installation. the rapid change of voltages and flows of cu rrent which can occur as a result of the operation of a lightning protection device ca n induce electromagnetic disturbances into adjacent equipment. ? target of the iec 61000-4-5 is to provide a model to simulate these surges and then to be able to check if the equipment is able to survive them.
docid024389 rev 1 3/11 AN4275 iec 61000-4-5 definition 2 iec 61000-4-5 definition 2.1 classes and voltage levels the standard specifies different classes depending on where the equipment is installed. for each class a corresponding peak voltage is applicable (see table 1 ). starting at a 500 v surge, it is generally required to protect the equipment with a specific device. 2.2 surge generator the generator used to model the surge is described in figure 1 . figure 1. iec 61000-4-5 surge generator in open mode, the generator delivers a 1.2 s/5 0 s voltage waveform, and in short circuit, the current waveform is 8/20 s. this kind of generator is call ed a combination wave generator. the surge is shown on figure 2 and figure 3 . table 1. classes and voltage levels class environment voltage level 0 well protected environment, often in a special room 25 v 1 partially protected environment 500 v 2 electrical environment where the cables are well separated, even at short runs 1 kv 3 electrical environment where power and signal cables run in parallel 2 kv 4 electrical environment where the interconnections include outdoor cables along with the power cable, and cables are used for both electronics and electric circuits 4 kv 5 electrical environment for electronic equipment connected to telecommunication cables and overhead power lines in a non-densely populated area test level 4 1.2 s/50 s surge generator source r out = 2  r ext
iec 61000-4-5 definition AN4275 4/11 docid024389 rev 1 figure 2. voltage waveform in open circuit figure 3. current waveform in short circuit for the same environment, there is a distinction between power lines and data lines, and an additional serial resistance (r ext ) may be required between the dut (device under test) and the surge generator. the selection of the source impedance (r out + r ext ) depends on the kind of equipment to be protected: ? the 2 ?? impedance represents the source impedance of the low-voltage power supply network. the generator is used alone wi th its effective output impedance of 2 ? . the surge is applied in a differential mode. ? the 12 ? (10 ? + 2 ? ) impedance represents the source impedance of the low-voltage power supply network and ground (common mode). a generator with an additional resistor of 10 ? in series is used. ? the effective 42 ? (40 ? + 2 ? ) impedance represents the source impedance between all other lines and ground. a generator with an additional resistance of 40 ? in series is used. as protection devices are sized with the surge current, table 2 shows the maximum peak current values depending on voltage level and r ext when surge generator is short circuited. 1,2 s 30% t a o 1 0,0 0,1 0,3 0,5 0,9 1,0 u t b 50 s 20% 30% max. t c o 1 0,0 0,1 0,5 0,9 1,0 i t b 2 20 % 0 s 8 20% s 30% max.
docid024389 rev 1 5/11 AN4275 iec 61000-4-5 definition test schematics are shown in figure 4 and figure 5 . figure 4. differential mode test set-up figure 5. common mode test set-up table 2. maximum peak current values depending on voltage level and r ext class 0 class 1 class 2 class 3 class 4 25 v 500 v 1 kv 2 kv 4 kv req = 42 ? 0.6 a 12 a 24 a 48 a 96 a req = 12 ? 2.1 a 42 a 84 a 167 a 334 a req = 2 ? 12.5 a 250 a 500 a 1000 a 2000 a l n pe decoupling network combination wave generator ac (dc) power supply network r ext = 0 equipment under test l n pe r ext = 10 decoupling network combination wave generator ac (dc) power supply network equipment under test
iec 61000-4-5 definition AN4275 6/11 docid024389 rev 1 figure 4 and figure 5 show the test schematics when the equipment is connected to power lines. for other types of lines, the decoupling network is slightly different on both line-to-line and line-to-ground tests. furthermore the test must be done with r ext = 40 ?? (see figure 6 ). figure 6. iec 61000-4-5 multi-line test set-up in practice, this surge is applied to equipme nt and not to a specific protection device. if the protection device is directly located at the input of the e quipment, the protection device has to withstand the complete surge. in some cases, the protection devi ce is not located at the input but somewhere in the middle of a board and then the protection device sees a slightly different surge. r ext =0 4 decoupling network combination wave generator e ent quipm under test protection equipm ent auxillary equipm ent
docid024389 rev 1 7/11 AN4275 protection devices 3 protection devices the device used to protect against iec 61000-4- 5 is generally a clamping device located in parallel with the circuit to be protected. this pr otection device limits the voltage to a specified value v cl (clamping voltage) by absorbing the surge current. its surge current capability is specified in its datasheet: i pp (peak pulse current). figure 7 gives the i/v characteristics of a clamping device. figure 7. i/v characteristics of a unidirectional clamping devices the goal of a protection devic e is to survive the surge (i pp ), and to protect the equipment by limiting the surge voltage (v cl ) below the maximum admissible voltage of the equipment/circuit. i pp protection the i pp of the protection must be defined according to the surge. in order to withstand a surge, a protection device should have an i pp (8/20 s surge) higher than the peak current generated by the standard. it is worthless to choose a protection defined by a 10/1000 s surge (this surge is dedicated to telecommunication lines) when the standard requires to comply with 8/20 s. st has been specifying its protection devices wit h 10/1000 s and 8/20 s surges for years. trends toward optimized protection in cost and in size leads us to produce dedicated protection devices specified according to iec 61000-4-5. v cl protection to protect a circuit from a surge, the protection device should have a v cl (8/20 s surge) lower than the maximum voltage the circuit can withstand. using a unidirectional device is safer as clamping voltage will be limited to v cl in one direction and to a forward voltage on the other direction. bidirectional device must be used only if the application requires to accept a reverse plug-in (on dc power lines) or if located on ac lines. i rm v rm v cl v i off-state area working area in case of positive surges working area in case of negative surges i pp
pep01-5841 as an example AN4275 8/11 docid024389 rev 1 4 pep01-5841 as an example this device is dedicated to the protection of power supplies of poe in pse side. typically poe power supply is 0 to -48 v. this protec tion device embeds 4 cells to protect against iec 61000-4-5 1 kv under 42 ?? which leads to a 24 a surge current.topology is given on figure 8 . figure 8. pep01-5841 functional diagram as the pep01-5841 has been designed to prot ect against iec61000-4-5, specified current capability (i pp ) of each cell is 24 a ( figure 8 ). this complies with the i pp protection requirement (capab ility to withstand the surge). the capability to protect is achieved with the v cl max limited to 100 v. the reason for the 100 v max is to avoid failure of the pmos or the pse controller generally using a technology typically around 110 or 120 v rated 100 v in the datasheet. table 3. electrical characteristics - values (t amb = 25 c) type i rm max @ v rm v br @i r (1) 1. pulse test: t p < 50 ms 8/20 s v cl @i pp r d (2) 2. to calculate maximum clamping voltage at other surge level, use the following formula: v clmax = r d x i pp + v br max 25 c 85 c min. typ. max. max. a a v v ma v a ? pep01-5841 0.2 1 58 64.4 67.8 71.2 1 100 24 1.2 ps1 1 ps2 4 ps3 5 ps4 8 gnd 2-3-6-7 all gnd pins must be connected to gnd
docid024389 rev 1 9/11 AN4275 conclusion 5 conclusion in most countries it is mandatory to comply with the iec 61000-4 series. most of the protection device s are rated with esd capability bu t only a few of them are rated with the surge corresponding to iec 61000-4-5. using the correct protection designed to comply with iec 61000-4-5 is an insurance to get reliable equipment and to avoid costly quality field returns to keep a good brand image. st has developed a range of devices rated according to iec 61000-4-5. for more information, go to the st.com web site and follow the links to the products for power discretes and modules for protection devices. iec 61000-4-5 compliant devices are listed under eos 8/20 microsecon d surge protection (see figure 9 ). figure 9. eos 8/20 s surge protection the use of an iec 61000-4-5 rated protection limits the number of tests to be performed before certification, saves cost and time and reduces the number of quality returns.
revision history AN4275 10/11 docid024389 rev 1 6 revision history table 4. document revision history date revision changes 06-aug-2013 1 initial release.
docid024389 rev 1 11/11 AN4275 please read carefully: information in this document is provided solely in connection with st products. stmicroelectronics nv and its subsidiaries (?st ?) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described he rein at any time, without notice. all st products are sold pursuant to st?s terms and conditions of sale. purchasers are solely responsible for the choice, selection and use of the st products and services described herein, and st as sumes no liability whatsoever relating to the choice, selection or use of the st products and services described herein. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. i f any part of this document refers to any third party products or services it shall not be deemed a license grant by st for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoev er of such third party products or services or any intellectual property contained therein. unless otherwise set forth in st?s terms and conditions of sale st disclaims any express or implied warranty with respect to the use and/or sale of st products including without limitation implied warranties of merchantability, fitness for a parti cular purpose (and their equivalents under the laws of any jurisdiction), or infringement of any patent, copyright or other intellectual property right. st products are not authorized for use in weapons. nor are st products designed or authorized for use in: (a) safety critical applications such as life supporting, active implanted devices or systems with product functional safety requirements; (b) aeronautic applications; (c) automotive applications or environments, and/or (d) aerospace applications or environments. where st products are not designed for such use, the purchaser shall use products at purchaser?s sole risk, even if st has been informed in writing of such usage, unless a product is expressly designated by st as being intended for ?automotive, automotive safety or medical? industry domains according to st product design specifications. products formally escc, qml or jan qualified are deemed suitable for use in aerospace by the corresponding governmental agency. resale of st products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by st for the st product or service described herein and shall not create or extend in any manner whatsoev er, any liability of st. st and the st logo are trademarks or registered trademarks of st in various countries. information in this document supersedes and replaces all information previously supplied. the st logo is a registered trademark of stmicroelectronics. all other names are the property of their respective owners. ? 2013 stmicroelectronics - all rights reserved stmicroelectronics group of companies australia - belgium - brazil - canada - china - czech republic - finland - france - germany - hong kong - india - israel - ital y - japan - malaysia - malta - morocco - philippines - singapore - spain - sweden - switzerland - united kingdom - united states of america www.st.com